Selected:

Phase and feeder live identifier

Phase and feeder live identifier

This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.

Applications: Helps to balance the loads on the phases of the low voltage network

Category:

2082total visits,0visits today

Description

Phase and feeder live identifier

 

USE :

This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.

Applications: Helps to balance the loads on the phases of the low voltage network

Simple to use: The Central Unit (CU) is connected to all the outgoing lines on a supply substation. The Line Unit (LU), connected to any points of the network (customer, connection box, …), automatically provides you with all the useful information:
– Local voltage measurement
– Phase indication L1, L2 or L3
– Feeder or circuit From 1 to 6 (9 or 12)
– Substation. (CU code.) From 1 to 8
– Didactic operating mode on the Central Unit

TECHNICAL SPECIFICATIONS :

Central Unit: FC3000 UC
Nominal voltage (phase-neutral): 115 Vrms to 230 Vrms (200 Vrms to 400 Vrms between phases)
Maximum rated voltage: 440 Vrms (between phases, and between phase and neutral)
Minimum operating voltage: 200 Vrms between phases
Network frequency: 50 or 60Hz
Input plugs L1-L2-L3-Neutral: Ø 4 mm male IP2X (at the end of the power lead)
Functions: automatic and manual modes English and French
Inputs protection: by 3 rapid fuse holders HPC (4 A) Ø 5mm x L=20 mm
Overvoltage category: 600 V Cat.IV
IP: IP51 (IP67 in closed case)
Dimensions: 300 x 230 x 85 mm
Weight: 2,35 kgDetection coils:
Number: 6 for FC30006, 9 for FC30009, 12 for FC300012
Identification: by colour coded ring(s)
Loop diameter: Ø 120 mmLine Unit: FC3000 UL
Nominal voltage: 230 Vrms (between phase terminal and neutral terminal)
Maximum rated voltage: 440 Vrms (between phase terminal and neutral terminal)
Power supply: 4 alkaline batteries 1.5 V AA
Autonomy: over 1000 detections
Inputs protection: Rapid fuse holder HPC (KTK-6 / 6 A) Ø 10mm x L=38 mm
Overvoltage category: 600 V Cat.IV
IP: IP54
Approximate dimensions: 250 (235) x 130 x 65 mm
Protection: shockproof rubber-type shell case
Weight: 1.4 kg with shell case, lead, test probes and alligator clipsComplete unit
• Synthetic carry and storage case, IP67 when closed
• Operating temperature: from 0°C to +40°C / Hygrometry < 90% non condensing
• Storage and transport temperature: from -20℃ to +70°C
ADVANTAGES :

Safety of the operator and the installations guaranteed:
Category IV device protected by HRC fuses
Insulated connection accessoriesReliable;
Feeder identification signal secured by “drawn current” signal
Information re circulated on the network by PLC
Built-in self-test
Sealed LU protected against outside risksA robust, complete set designed for field use:
Central Unit in a heavy duty sealed case, also used to store and carry the Line Unit as well as all the accessories
Line Unit protected by a shockproof shell made of a soft material

2082total visits,0visits today