Phase and feeder live identifier
This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.
Applications: Helps to balance the loads on the phases of the low voltage network
2082total visits,0visits today
Description
Phase and feeder live identifier
|
USE :
This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds. Applications: Helps to balance the loads on the phases of the low voltage network Simple to use: The Central Unit (CU) is connected to all the outgoing lines on a supply substation. The Line Unit (LU), connected to any points of the network (customer, connection box, …), automatically provides you with all the useful information: |
TECHNICAL SPECIFICATIONS :
Central Unit: FC3000 UC
Nominal voltage (phase-neutral): 115 Vrms to 230 Vrms (200 Vrms to 400 Vrms between phases) Maximum rated voltage: 440 Vrms (between phases, and between phase and neutral) Minimum operating voltage: 200 Vrms between phases Network frequency: 50 or 60Hz Input plugs L1-L2-L3-Neutral: Ø 4 mm male IP2X (at the end of the power lead) Functions: automatic and manual modes English and French Inputs protection: by 3 rapid fuse holders HPC (4 A) Ø 5mm x L=20 mm Overvoltage category: 600 V Cat.IV IP: IP51 (IP67 in closed case) Dimensions: 300 x 230 x 85 mm Weight: 2,35 kgDetection coils: Number: 6 for FC30006, 9 for FC30009, 12 for FC300012 Identification: by colour coded ring(s) Loop diameter: Ø 120 mmLine Unit: FC3000 UL Nominal voltage: 230 Vrms (between phase terminal and neutral terminal) Maximum rated voltage: 440 Vrms (between phase terminal and neutral terminal) Power supply: 4 alkaline batteries 1.5 V AA Autonomy: over 1000 detections Inputs protection: Rapid fuse holder HPC (KTK-6 / 6 A) Ø 10mm x L=38 mm Overvoltage category: 600 V Cat.IV IP: IP54 Approximate dimensions: 250 (235) x 130 x 65 mm Protection: shockproof rubber-type shell case Weight: 1.4 kg with shell case, lead, test probes and alligator clipsComplete unit • Synthetic carry and storage case, IP67 when closed • Operating temperature: from 0°C to +40°C / Hygrometry < 90% non condensing • Storage and transport temperature: from -20℃ to +70°C |
ADVANTAGES :
Safety of the operator and the installations guaranteed:
Category IV device protected by HRC fuses Insulated connection accessoriesReliable; Feeder identification signal secured by “drawn current” signal Information re circulated on the network by PLC Built-in self-test Sealed LU protected against outside risksA robust, complete set designed for field use: Central Unit in a heavy duty sealed case, also used to store and carry the Line Unit as well as all the accessories Line Unit protected by a shockproof shell made of a soft material |
2082total visits,0visits today
Reviews
There are no reviews yet.