Selected:

Phase and feeder live identifier

Phase and feeder live identifier

This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.

Applications: Helps to balance the loads on the phases of the low voltage network

Category:

2064total visits,0visits today

Description

Phase and feeder live identifier

 

USE :

This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.

Applications: Helps to balance the loads on the phases of the low voltage network

Simple to use: The Central Unit (CU) is connected to all the outgoing lines on a supply substation. The Line Unit (LU), connected to any points of the network (customer, connection box, …), automatically provides you with all the useful information:
– Local voltage measurement
– Phase indication L1, L2 or L3
– Feeder or circuit From 1 to 6 (9 or 12)
– Substation. (CU code.) From 1 to 8
– Didactic operating mode on the Central Unit

TECHNICAL SPECIFICATIONS :

Central Unit: FC3000 UC
Nominal voltage (phase-neutral): 115 Vrms to 230 Vrms (200 Vrms to 400 Vrms between phases)
Maximum rated voltage: 440 Vrms (between phases, and between phase and neutral)
Minimum operating voltage: 200 Vrms between phases
Network frequency: 50 or 60Hz
Input plugs L1-L2-L3-Neutral: Ø 4 mm male IP2X (at the end of the power lead)
Functions: automatic and manual modes English and French
Inputs protection: by 3 rapid fuse holders HPC (4 A) Ø 5mm x L=20 mm
Overvoltage category: 600 V Cat.IV
IP: IP51 (IP67 in closed case)
Dimensions: 300 x 230 x 85 mm
Weight: 2,35 kgDetection coils:
Number: 6 for FC30006, 9 for FC30009, 12 for FC300012
Identification: by colour coded ring(s)
Loop diameter: Ø 120 mmLine Unit: FC3000 UL
Nominal voltage: 230 Vrms (between phase terminal and neutral terminal)
Maximum rated voltage: 440 Vrms (between phase terminal and neutral terminal)
Power supply: 4 alkaline batteries 1.5 V AA
Autonomy: over 1000 detections
Inputs protection: Rapid fuse holder HPC (KTK-6 / 6 A) Ø 10mm x L=38 mm
Overvoltage category: 600 V Cat.IV
IP: IP54
Approximate dimensions: 250 (235) x 130 x 65 mm
Protection: shockproof rubber-type shell case
Weight: 1.4 kg with shell case, lead, test probes and alligator clipsComplete unit
• Synthetic carry and storage case, IP67 when closed
• Operating temperature: from 0°C to +40°C / Hygrometry < 90% non condensing
• Storage and transport temperature: from -20℃ to +70°C
ADVANTAGES :

Safety of the operator and the installations guaranteed:
Category IV device protected by HRC fuses
Insulated connection accessoriesReliable;
Feeder identification signal secured by “drawn current” signal
Information re circulated on the network by PLC
Built-in self-test
Sealed LU protected against outside risksA robust, complete set designed for field use:
Central Unit in a heavy duty sealed case, also used to store and carry the Line Unit as well as all the accessories
Line Unit protected by a shockproof shell made of a soft material

2064total visits,0visits today

Reviews

There are no reviews yet.

Be the first to review “Phase and feeder live identifier”

Your email address will not be published. Required fields are marked *

Close Menu
×
×

Cart

Call Now ButtonCall Now: 9347021234